AI-Deep Learning-based Morphometric Assessment of Peri-implant Tissues: A Comparative Study of 2D and 3D Radiographic Modalities
DOI:
https://doi.org/10.7546/CRABS.2026.11.17Keywords:
artificial intelligence, deep learning, convolutional neural networks, peri-implantitis, cone-beam computed tomography, panoramic radiographyAbstract
Dental implant therapy has expanded a lot, which means we now need more reliable imaging methods to early detect peri-implant diseases. Artificial intelligence (AI), mainly convolutional neural networks (CNNs), is a great way to help dental implant radiologists make a diagnosis. This paper aims to evaluate an AI system in comparison to different imaging methods, namely traditional 2D panoramic radiographs (OPG) and 3D cone beam computed tomography (CBCT), in detecting and classifying peri-implant conditions including peri-implantitis (PI), retrograde peri-implantitis (RPI), and prosthetically induced bone loss. In total, the authors analyzed 824 implants (428 healthy, 396 diseased) from OPG and CBCT images. The authors selected DenseNet121, a CNN model, and used transfer learning to train it to classify lesions. The diagnostic performance of the model was measured by accuracy sensitivity specificity, F1-score, and ROC curve area (AUC). The Hanley and McNeil methods were used for modality comparisons. The model exhibited moderate to strong diagnostic capabilities for both imaging techniques with the ROC AUC values between 0.630 and 0.755. CBCT gave a higher accuracy result in detecting maxillary retrograde peri-implantitis (AUC: 0.710 vs. 0.635; ρ = 0.016) whereas OPG was superior in identifying mandibular peri-implantitis (AUC: 0.755 vs. 0.630; ρ < 0.001). On examining prosthetically induced bone loss, both methods yielded similar outcomes. The results show that the CNN models are reliable in diagnosing peri-implant lesions, but a person’s diagnostic performance would depend on the lesion’s type and its anatomical location. CBCT would be more suitable for complex apical lesions, whereas OPG is still good for assessing marginal bone changes.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Proceedings of the Bulgarian Academy of SciencesCopyright (c) 2022 Proceedings of the Bulgarian Academy of Sciences
Copyright is subject to the protection of the Bulgarian Copyright and Associated Rights Act. The copyright holder of all articles on this site is Proceedings of the Bulgarian Academy of Sciences. If you want to reuse any part of the content, please, contact us.

